CANedge1: 2x CAN Bus Data Logger (SD + RTC)

Giá bán: Liên hệ

Mã sản phẩm: CANedge1

Thương hiệu: CSS

Tình trạng: Còn hàng

Thông tin đặt hàng:

CANedge1: 2x CAN Bus Data Logger (SD + RTC)

Tư vấnhotline0965 746 247

CANedge1: 2x CAN Bus Data Logger (SD + RTC)

The plug & play 2xCAN/LIN logger records timestamped CAN data (Classical/CAN FD) to the extractable 8 GB industrial SD card.

It's extremely easy-to-use: Simply power the device via your CAN bus connector to start logging raw CAN data. Extract the data and process it using 100% free open source software/API tools - incl. J1939/OBD2 DBC conversion & graphical plots.

The CANedge1 is ideal for monitoring CAN bus systems over long periods - e.g. for legal purposes, vehicle development, diagnostics, maintenance or research.

Simple CAN Logger Easy Use Dummies

PLUG & PLAY

Log data out-the-box. Standalone - no PC required. Power via CAN connector

Pro CAN Bus Data Logger Specs High Performance

PRO SPECS

Extractable 8-32 GB SD. 2xCAN/LIN. CAN FD. Zero data loss. 50 µs RTC resolution. MDF4

Compact Small CAN Bus Logger Rugged

SO SMALL

Only 8 x 5 x 2 CM. 100G. Aluminium enclosure. 4 LEDs. Configurable 5V power out (CH2)

Advanced CAN ID filters Transmit OBD2 J1939

CONFIGURABLE

Advanced filters. Transmit lists. Triggers. Cyclic logging. Silent mode

Over-The-Air Configuration Firmware Online Telematics Dongle

FAST & SECURE

Industrial SD card. Read data at 80 MB/s. Data encryption for GDPR/CCPA

Open Source API Free CAN Bus Software MF4 MDF

INTEROPERABLE

Free open source software/API tools. Convert data to e.g. CSV, ASC, TRC. DBC convert & plot.

TECHNICAL SPECIFICATION

GENERAL  
Functionality Standalone data logger with SD card and 2xCAN/LIN channels (incl. CAN FD)
Firmware Supports free firmware updates for adding features
Configuration Configuration files based on the popular open source JSON schema concept
Software Free open source editor tool for easy device configuration (offline/online version available)
  Free open source asammdf software & API for editing, DBC converting & plotting MDF4 data
  Free open source C++ MDF4 converters - drag & drop log files to convert into e.g. CSV, ASC, PCAP
Safety CE, FCC, IC and RoHS certified (see the manual)
  Tested for voltage transients (emissions/immunity), ISO 7637-2:2011, by TÜV SÜD (see the manual)
Warranty 1-year warranty
Support Free, fast & high quality support
Origin Denmark
CAN BUS  
Channels 2 x CAN/CAN FD channels
Standard ISO 11898: Compliant with CAN (up to 1 Mbit/s) and ISO & Bosch CAN FD (up to 5 Mbit/s)
Protocols Log raw data from CAN based protocols (J1939, FMS, CANopen, NMEA 2000, OBD2, ...)
Identifiers Compliant with CAN specifications 2.0A (11-Bit ID) and 2.0B (29-Bit ID)
Bit-Rate Auto-Detect Bit rate can be auto-detected or set manually
Retransmission Configurable retransmission of frames that have lost arbitration or been disturbed by errors
Transceiver Protection ±16 kV HBM ESD, ±15 kV IEC ESD, ±70 V bus fault, short circuit
  Common mode input voltage: ±30 V
  TXD dominant timeout (prevents network blocking in the event of a failure)
LIN BUS  
Channels 2 x LIN channels (Slaves)
Standard Compliant with LIN 2.0 up to 20 Kbit/s ("enhanced" checksum format)
Transceiver Protection ±8 kV HBM ESD, ±1.5 kV CDM, ±58 V bus fault
  TXD dominant timeout (prevents network blocking in the event of a failure)
DATA LOGGING  
SD Card 8 GB extractable Class 10 industrial micro SD (SDHC) included (optional 32GB) - read at 80 MB/s
Parallel CAN/LIN Record data from up to 2 x CAN channels + 2 x LIN channels, simultaneously
Real-Time Clock Yes - CAN frames are date & timestamped with 50 microsecond resolution
  The RTC can be configured to match local time zones (default: UTC)
Log File Format Log data in industry standard binary MDF4 (easily convert to e.g. CSV, ASC, pandas, MATLAB, ...)
Data Compression Configurable embedded log file zipping (~50-80% size reduction)
Silent Mode Configurable silent mode: Restricted (acknowledge only) or monitoring (zero transmission)
Filters 128/64 regular/extended ID filters per channel (range, mask, acceptance, rejection, prescaling)
Transmit Transmit lists of CAN frames per channel (single-shot/periodic) - e.g. for OBD2 requests
Cyclic Logging Optional cyclic logging mode (oldest log file is deleted when SD card is full)
Advanced Triggers Control signal lets you start/stop logging based on custom CAN IDs & data thresholds
CAN Heartbeat Optionally transmit heartbeat CAN frame with device status, storage used & RTC time
File Split Configurable log file split size (by size: 1-512 MB and/or by time period: 0-86400s)
Power Safe 100% power safe data logging - no file corruption when disconnected
Unique Device ID Each device has a globally unique ID ensuring unique log file naming
Data Encryption Log files can be encrypted at rest on the SD card for security/GDPR/CCPA purposes
ELECTRICAL  
Input Supply +7V to +32V DC via the Channel 1 DB9 (e.g. via CAN connector power pin)
Power Consumption Extremely low (~1 W) - no risk of battery drainage
Protection Reverse voltage protection on CAN-bus supply
  Transient voltage event protection on supply lines
MECHANICAL  
Enclosure & Weight Compact aluminium enclosure: 52.5 x 81.4 x 24.5 mm (L x W x H), 100 grams
Connector 2 x Standard D-sub 9 (DB9) connectors (OBD2/J1939 adaptors optional)
Pin-Out See the product manual for the DB9 connector pin-outs
Configurable Power Out Channel 2 can be configured to supply 5V to 1-3 external modules
LEDs Logger status via 4 external LEDs: Power, CH1, CH2, Memory
Temperature Operating temperature (parts): -25degC to +70degC
IP Rating IP Rating 40

 

USE CASES

The CANedge1 is a powerful, standalone CAN logger for standalone CAN logging, diagnostics and development.

Note: If you need to remotely collect data via WiFi/3G/4G, check out the CANedge2.Fleet Monitoring Offline Data Storage SD Card

Vehicle 'black box'

Need to monitor data from your vehicle fleet?

The CANedge1 is ideal for recording data over long periods from fleets - incl. cars (via OBD2) and heavy-duty vehicles (via J1939). With filters, compression & cyclic logging you can log years of data. Ideal for e.g. warranty/legal data storage or optimization.


 

Rare issue identification

Need to identify a rare, but critical issue?

If you have e.g. production equipment that periodically exhibts an issue the CANedge1 is a great diagnostics tool. Simply connect it and leave it in. If the issue occurs, you can extract the raw data, DBC convert it and plot it for quick diagnostics.

Rare Issue Diagnostics Machinery Maintenance


 

Vehicle Equipment Optimization Development J1939 CAN

Equipment development & optimization

Need to optimize your CAN based equipment based on long-term data?

The standalone CANedge1 is ideal for recording data from equipment deployed in the field: It's durable, compact and simple to install. You can e.g. pre-configure the device - and ship it to the end-users for installation.

 

 

"The CANedge1 let us collect data from our fleet of test EVs
I would definitely recommend it to anyone who wants a CAN data logger"
— Yettella Siva, Bosch India

Để được tư vấn miễn phí

Quý khách hàng vui lòng để lại thông tin bên dưới

zalo